In Mesa, near East Decatur Street and North 62nd Street performing a diagnostic on an Amana package heat pump. Upon arrival, cycled unit into cooling mode. Unit would cycle for 12-15 minutes and turn off with thermostat still calling for cooling. No 24 volts present out of defrost board. Checked all pressure switches and all closed circuits. Defrost board replaced on 04/03/2020. Bypassed defrost board until board can be ordered and re installed. Upon departure, unit is working properly and within manufacturer specifications.

Near E Decatur St, Mesa, AZ 85205
Mesa, AZ - In Mesa, near East Decatur Street and North 62nd Street performing a diagnostic on an Amana package heat pump. Upon arrival, cycled unit into cooling mode. Unit would cycle for 12-15 minutes and turn off with thermostat still calling for cooling. No 24 volts present out of defrost board. Checked all pressure switches and all closed circuits. Defrost board replaced on 04/03/2020. Bypassed defrost board until board can be ordered and re installed. Upon departure, unit is working properly and within manufacturer specifications.
Tom G.

Tom G.

In Mesa, near West Baseline Road and South Longmore performing a diagnostic. Customer recently had another contractor out to work on system. Found drain line clogged and primary pan leaking at secondary fitting. Blew out line. Applied silicone to rusted out section of pan. Cleaned tap underneath sink. Service completed. Unit is very old and I don't believe they make replacement pans for it.

Near W Baseline Rd, Mesa, AZ 85202
Mesa, AZ - In Mesa, near West Baseline Road and South Longmore performing a diagnostic. Customer recently had another contractor out to work on system. Found drain line clogged and primary pan leaking at secondary fitting. Blew out line. Applied silicone to rusted out section of pan. Cleaned tap underneath sink. Service completed. Unit is very old and I don't believe they make replacement pans for it.
Brian S.

Brian S.

In Mesa, near East Glade Avenue and South Somerset performing Fall preventative maintenance on an Amana furnace. Cycled system on into heating mode. Checked gas line and flue piping; both sealed and proper. Removed and cleaned flame sensor, then re-installed. Checked all safeties, back pressure safety switch shutting down properly. Limit switches are all testing proper. Burners and igniter are working proper. Changed return air filter and checked splits. System is running within manufacturer specifications at this time.

Near E Glade Ave, Mesa, AZ 85206
Mesa, AZ - In Mesa, near East Glade Avenue and South Somerset performing Fall preventative maintenance on an Amana furnace. Cycled system on into heating mode. Checked gas line and flue piping; both sealed and proper. Removed and cleaned flame sensor, then re-installed. Checked all safeties, back pressure safety switch shutting down properly. Limit switches are all testing proper. Burners and igniter are working proper. Changed return air filter and checked splits. System is running within manufacturer specifications at this time.
Brian S.

Brian S.

In Mesa, near East Hope Street and North 24th Street performing a diagnostic on a Bryant condenser. On arrival, customer stated he had another company out over the holiday weekend, and they had found system low on Freon. I performed a leak search on the system and found a lot of oil coming off of the condenser coil. Multiple hits out of the condensing coil from the leak detector. Will call home warranty co. to order a new condensing coil.

Near N Gaylord Cir, Mesa, AZ 85213
Tom G.

Tom G.

In Mesa, near East Las Palmas Grand and South 206th Street performing routine seasonal maintenance on an Amana package heat pump. Upon departure, system is working within manufacturer specifications.

Near S Ellsworth Rd, Mesa, AZ 85209
Mesa, AZ - In Mesa, near East Las Palmas Grand and South 206th Street performing routine seasonal maintenance on an Amana package heat pump. Upon departure, system is working within manufacturer specifications.
Tom G.

Tom G.

In Mesa, near East Main Street and North Greenfield Road performing routine seasonal maintenance on a Carrier package heat pump. Service was completed in accordance with maintenance checklist. System is running within manufacturer specifications.

Near N Greenfield Rd, Mesa, AZ 85205
Mesa, AZ - In Mesa, near East Main Street and North Greenfield Road performing routine seasonal maintenance on a Carrier package heat pump. Service was completed in accordance with maintenance checklist. System is running within manufacturer specifications.
Tom G.

Tom G.

In Mesa, near East Baseline Road and North Kiowa Avenue performing routine maintenance on 2 Carrier package heat pumps. Both systems were recently replaced and working properly upon departure.

Near E Baseline Rd, Mesa, AZ 85206
Mesa, AZ - In Mesa, near East Baseline Road and North Kiowa Avenue performing routine maintenance on 2 Carrier package heat pumps. Both systems were recently replaced and working properly upon departure.
Leonardo G.

Leonardo G.

In Mesa, near Holmes Park performing a diagnostic on a leaking 3.5 Ton Goodman heat pump split system. Upon arrival, found drywall damage in the kitchen/living area as well as water coming from light fixture in kitchen due to platform being wet. In the attic, found platform wet from improper glued fitting. Also, found one fitting not glued and secondary drain pan full of water. I re-glued fitting, replaced male thread, and PVC; made it to where primary line sloped downward. Flushed drain line, vacuumed all water from drain pan and also let homeowner know if issue continues to contact a plumber. Upon departure, system is functioning properly and within manufacturer specifications.

Near S Greenfield Rd, Mesa, AZ 85206
Mesa, AZ - In Mesa, near Holmes Park performing a diagnostic on a leaking 3.5 Ton Goodman heat pump split system. Upon arrival, found drywall damage in the kitchen/living area as well as water coming from light fixture in kitchen due to platform being wet. In the attic, found platform wet from improper glued fitting. Also, found one fitting not glued and secondary drain pan full of water. I re-glued fitting, replaced male thread, and PVC; made it to where primary line sloped downward. Flushed drain line, vacuumed all water from drain pan and also let homeowner know if issue continues to contact a plumber. Upon departure, system is functioning properly and within manufacturer specifications.
Brian S.

Brian S.

In Mesa, near East Elmwood Street and North 96th Street performing a quality inspection on a newly installed 5 Ton, 14 Seer, Goodman Package Heat Pump. Changed out thermostat for customer.

Near E Elmwood St, Mesa, AZ 85207
Mesa, AZ - In Mesa, near East Elmwood Street and North 96th Street performing a quality inspection on a newly installed 5 Ton, 14 Seer, Goodman Package Heat Pump. Changed out thermostat for customer.
Brian S.

Brian S.

In Mesa, near East Encanto Street and East Fairfield Street performing seasonal routine maintenance on 2 Amana units. Both units are in working order and maintenance was done in accordance with maintenance checklist.

Near E Encanto St, Mesa, AZ 85205
Mesa, AZ - In Mesa, near East Encanto Street and East Fairfield Street performing seasonal routine maintenance on 2 Amana units. Both units are in working order and maintenance was done in accordance with maintenance checklist.
Tom G.

Tom G.

In Mesa, near East 10th Avenue and South Pioneer performing a diagnostic on a roof top unit. Found fan motor seized and fan blade damaged. Replaced motor, blade, and capacitor. Home is very warm and will take a few days to cool to desired temperature. Service complete.

Near E 10th Ave, Mesa, AZ 85204
Tom G.

Tom G.

In Mesa, near East Fairfield Street and North Amber Circle replacing a 825 rpm fan motor with 7.5 uf capacitor. This York system is in really bad condition and needs replacement. Will need to see if compressor holds with repair.

Near E Fairfield St, Mesa, AZ 85203
Mesa, AZ - In Mesa, near East Fairfield Street and North Amber Circle replacing a 825 rpm fan motor with 7.5 uf capacitor. This York system is in really bad condition and needs replacement. Will need to see if compressor holds with repair.
Tom G.

Tom G.

In Mesa, near Signal Butte Floodway and North Vincent Circle performing a diagnostic on a Trane condenser. Fan motor was seized and capacitor swollen upon arrival. Replaced capacitor and motor. Charged system with 3 lbs of R22. Unit is working properly upon departure.

Near N Vincent Cir, Mesa, AZ 85207
Mesa, AZ - In Mesa, near Signal Butte Floodway and North Vincent Circle performing a diagnostic on a Trane condenser. Fan motor was seized and capacitor swollen upon arrival. Replaced capacitor and motor. Charged system with 3 lbs of R22. Unit is working properly upon departure.
Brian S.

Brian S.

In Mesa, AZ: DIAGNOSTIC- On arrival, found compressor not running. Checked run capacitor and found 1.1/5.8/440; should be at 40/5/440. Talked to customer about replacing capacitor and adding a hard start kit. Customer approved the 40/5/440 capacitor and declined the hard start kit. Installed new capacitor and cycled system on. Upon departure, system is running properly and within manufacturer specifications. Service complete. Return 91/Supply 71.

Near E Monte Ave, Mesa, AZ 85209
Mesa, AZ - In Mesa, AZ:  DIAGNOSTIC-  On arrival, found compressor not running. Checked run capacitor and found 1.1/5.8/440; should be at 40/5/440. Talked to customer about replacing capacitor and adding a hard start kit. Customer approved the 40/5/440 capacitor and declined the hard start kit. Installed new capacitor and cycled system on. Upon departure, system is running properly and within manufacturer specifications. Service complete. Return 91/Supply 71.
Leonardo G.

Leonardo G.

In Mesa, AZ: DIAGNOSTIC- Upon arrival, cycled unit into cooling mode. Found system low on charge about a pound or two. Recharged system to correct specification. Upon departure, unit is working properly and within manufacturer specifications.

Near E Kiva Ave, Mesa, AZ 85209
Mesa, AZ - In Mesa, AZ:  DIAGNOSTIC-  Upon arrival, cycled unit into cooling mode. Found system low on charge about a pound or two. Recharged system to correct specification. Upon departure, unit is working properly and within manufacturer specifications.
Brian S.

Brian S.

In Mesa, AZ: DIAGNOSTIC- Customer stated that George Brazil installed a new run capacitor on his system last week and told him he should change out system. Checked Freon levels; all in factory specification. Checked volt and amp draws. Compressor Rated 16.0/Actual 14.37. Outdoor fan motor Rated 2.0/Actual 1.05. System is 20 years old but running properly at this time. Service complete.

Near N 74th St, Mesa, AZ 85207
Mesa, AZ - In Mesa, AZ:  DIAGNOSTIC-  Customer stated that George Brazil installed a new run capacitor on his system last week and told him he should change out system. Checked Freon levels; all in factory specification. Checked volt and amp draws. Compressor Rated 16.0/Actual 14.37. Outdoor fan motor Rated 2.0/Actual 1.05. System is 20 years old but running properly at this time. Service complete.
Leonardo G.

Leonardo G.

In Mesa, AZ: PREVENTATIVE MAINTENANCE- Upon arrival, cycled unit into cooling mode. Replaced intake filters and took temperature reading from supply and return. At unit, cleaned and tightened electrical connections. Took volt and amp draws from components. Checked Freon levels with super heat and subcool. Upon departure, unit is working properly and within manufacturer specifications.

Near E Glade Ave, Mesa, AZ 85206
Mesa, AZ - In Mesa, AZ:  PREVENTATIVE MAINTENANCE-  Upon arrival, cycled unit into cooling mode. Replaced intake filters and took temperature reading from supply and return. At unit, cleaned and tightened electrical connections. Took volt and amp draws from components. Checked Freon levels with super heat and subcool. Upon departure, unit is working properly and within manufacturer specifications.
Brian S.

Brian S.

In Mesa, AZ: DIAGNOSTIC- Unit is running. Checked Freon levels R22 in factory specification. Checked volt and amp draws. Compressor rated at 20.7; actual is 20.00. ODF motor rated at 2.6, actual 1.69. Indoor blower rated at 6.0, actual 4.43. Capacitor is rated 55/5/440, actual 57.2/5.1/440. Compressor is high amping and wiring for compressor is melting. Also, Freon is foaming. Mega OHM tested the compressor findings showing in orange for caution. Would recommend upgrading the system. Service complete.

Near W Obispo Ave, Mesa, AZ 85202
Mesa, AZ - In Mesa, AZ:  DIAGNOSTIC-  Unit is running. Checked Freon levels R22 in factory specification. Checked volt and amp draws. Compressor rated at 20.7; actual is 20.00. ODF motor rated at 2.6, actual 1.69. Indoor blower rated at 6.0, actual 4.43. Capacitor is rated 55/5/440, actual 57.2/5.1/440. Compressor is high amping and wiring for compressor is melting. Also, Freon is foaming. Mega OHM tested the compressor findings showing in orange for caution. Would recommend upgrading the system. Service complete.
Tom G.

Tom G.

In Mesa, AZ: PREVENTATIVE MAINTENANCE- Completed maintenance service in accordance with maintenance checklist. Replaced Schrader valve and recharged system at time of service. Need to monitor evaporative coil for wear on future services. Service complete.

Near E Jensen St, Mesa, AZ 85207
Mesa, AZ - In Mesa, AZ:  PREVENTATIVE MAINTENANCE-  Completed maintenance service in accordance with maintenance checklist. Replaced Schrader valve and recharged system at time of service. Need to monitor evaporative coil for wear on future services. Service complete.
Tom G.

Tom G.

In Mesa, AZ: DIAGNOSTIC- Small leak from from water line to float. Tightened fitting to stop leak. Inspected all coolers during repair. Systems are working properly upon departure. Service complete.

Near E Falcon Dr, Mesa, AZ 85215
Mesa, AZ - In Mesa, AZ:  DIAGNOSTIC-  Small leak from from water line to float. Tightened fitting to stop leak. Inspected all coolers during repair. Systems are working properly upon departure. Service complete.
Leonardo G.

Leonardo G.

In Mesa, AZ: Upon arrival, cycled unit into cooling mode. Took temperature readings from supply and return. At unit, cleaned and tightened electrical connections. Took volts and amp draws from components. Checked Freon levels with super heat and subcool. Upon departure, unit is working properly and within manufacturer specifications.

Near E Decatur St, Mesa, AZ 85205
Mesa, AZ - In Mesa, AZ:  Upon arrival, cycled unit into cooling mode. Took temperature readings from supply and return. At unit, cleaned and tightened electrical connections. Took volts and amp draws from components. Checked Freon levels with super heat and subcool. Upon departure, unit is working properly and within manufacturer specifications.
Tom G.

Tom G.

In Mesa, AZ: Removed old pads and installed new straw pads with distribution lines; all new floats and pumps; cleaned out all evap coolers with pressure washer and tested each cooler. Cleaned up job site.

Near E Falcon Dr, Mesa, AZ 85215
Mesa, AZ - In Mesa, AZ:  Removed old pads and installed new straw pads with distribution lines; all new floats and pumps; cleaned out all  evap coolers with pressure washer and tested each cooler. Cleaned up job site.
Tom G.

Tom G.

in Mesa, AZ: Did financing paperwork for $5000. Remainder will be paid by check on completion. Pending parts before installation. Install will start at 6am.

Near E Falcon Dr, Mesa, AZ 85215
Brian S.

Brian S.

In Mesa, AZ: QUOTE FOR 8 VIRGIN COOLERS. CUSTOMER WANTS BID WITH ELECTRICITY RAN. AND ROOF SEALED AFTER CUTTING IN DROPS. ALSO POSSIBLE PERMITS INCLUDED. NEED TO GET WITH JOSH FOR PRICING.

Near S Dobson Rd, Mesa, AZ 85202
Mesa, AZ - In Mesa, AZ:  QUOTE FOR 8 VIRGIN COOLERS. CUSTOMER WANTS BID WITH ELECTRICITY RAN. AND ROOF SEALED AFTER CUTTING IN DROPS. ALSO POSSIBLE PERMITS INCLUDED. NEED TO GET WITH JOSH FOR PRICING.
Tom G.

Tom G.

In Mesa, AZ: MOREHART AC TO SERVICE AND REPAIR SIX EVAPORATIVE COOLER SYSTEMS. PRICING INCLUDES REPLACEMENT OEM ASPEN PAD SETS, 115v 15-25k PUMPS, 3/8 FLOATS, DRAIN KITS, AND NEW DISTRIBUTION LINES, AND BLEEDERS. IN ADDITION EACH SYSTEM WILL BE PRESSURE WASHED DURING REPAIRS. MOREHART AC IS NOT RESPONSIBLE FOR ANY DAMAGE TO ROOF DURING MAINTENANCE. PENDING CUSTOMER APPROVAL. Ump 454SPB 47451 Pads 70 420 pending pricing from ump

Near E Falcon Dr, Mesa, AZ 85215
Mesa, AZ - In Mesa, AZ:  MOREHART AC TO SERVICE AND REPAIR SIX EVAPORATIVE COOLER SYSTEMS. PRICING INCLUDES REPLACEMENT OEM ASPEN PAD SETS, 115v 15-25k PUMPS, 3/8 FLOATS, DRAIN KITS, AND NEW DISTRIBUTION LINES, AND BLEEDERS. IN ADDITION EACH SYSTEM WILL BE PRESSURE WASHED DURING REPAIRS. MOREHART AC IS NOT RESPONSIBLE FOR ANY DAMAGE TO ROOF DURING MAINTENANCE. PENDING CUSTOMER APPROVAL.
Ump 454SPB
47451
Pads 70 420 pending pricing from ump
Tom G.

Tom G.

In Mesa, AZ: Completed service in accordance with maintenance checklist, please refer to to list for photos and ratings. Customer had another contractor out to warranty evaporative coil. Recommend insulating suction line to prevent water damage to insulation and potential water in return. Fan is not mounted correctly in system. Door was not secured upon arrival. Please refer to provided video. Finally liquid line is rubbing on suction line due to line being pushed back for new filter drier. Recommend having contractor out to fix repairs. Service completed.

Near N Yucca Cir, Mesa, AZ 85201
Mesa, AZ - In Mesa, AZ:  Completed service in accordance with maintenance checklist, please refer to to list for photos and ratings. Customer had another contractor out to warranty evaporative coil. Recommend insulating suction line to prevent water damage to insulation and potential water in return. Fan is not mounted correctly in system. Door was not secured upon arrival. Please refer to provided video. Finally liquid line is rubbing on suction line due to line being pushed back for new filter drier. Recommend having contractor out to fix repairs. Service completed.
Leonardo G.

Leonardo G.

In Mesa, AZ: UPON ARRIVAL FOUND RETURN PANEL UNSEALED AND ALSO BREAKING AWAY FROM UNIT. PROPERLY FASTENED SCREWS TO RETURN PANEL AND RE SEALED PANEL AS WELL AS SUPPLY PANEL. HOMEOWNER HAVING AIRFLOW ISSUES WITH ONE OF THE BEDROOMS. NOTICED IN THE ATTIC THE DUCT WORK NEEDS TO BE STRAPPED UP AND ALSO SOME RUNS NEED TO BE RE RAN TO PREVENT KINKS IN DUCT WORK TO PREVENT AIR FLOW RESTRICTIONS. HOMEOWNER WILL CONTACT COMPANY THAT INSTALLED DUCT WORK .

Near E Grandview St, Mesa, AZ 85207
Mesa, AZ - In Mesa, AZ:  UPON ARRIVAL FOUND RETURN PANEL UNSEALED AND ALSO BREAKING AWAY FROM UNIT. PROPERLY FASTENED SCREWS TO RETURN PANEL AND RE SEALED PANEL AS WELL AS SUPPLY PANEL. HOMEOWNER HAVING AIRFLOW ISSUES WITH ONE OF THE BEDROOMS. NOTICED IN THE ATTIC THE DUCT WORK NEEDS TO BE STRAPPED UP AND ALSO SOME RUNS NEED TO BE RE RAN TO PREVENT KINKS IN DUCT WORK TO PREVENT AIR FLOW RESTRICTIONS. HOMEOWNER WILL CONTACT COMPANY THAT INSTALLED DUCT WORK .
Brian S.

Brian S.

In Mesa, AZ: CYCLED SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS, ALL IN FACTORY SPECIFICATION. CLEANED OUT CONTROL CABINET AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALL IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. CHANGED RETURN AIR FILTER AND CHECKED SPLITS, RETURN 76 SUPPLY 56. INDOOR COIL IS VERY DIRTY RECOMMEND AN INDOOR COIL CLEANING.

Near E Myrtle St, Mesa, AZ 85208
Tom G.

Tom G.

In Mesa, AZ: Completed service in accordance with maintenance checklist. Please refer to list for photos and ratings. System working properly upon departure.

Near E Neville Ave, Mesa, AZ 85209
Tom G.

Tom G.

In Mesa, AZ: Completed service in accordance with maintenance checklist. Please refer to list for photos and ratings. System working properly upon departure. Recommended replacing cooler due to age and condition. Customer said now is not a good time she will let us know.

Near E Main St, Mesa, AZ 85205
Brian S.

Brian S.

In Mesa, AZ: CYCLED SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS, ALL IN FACTORY SPECIFICATION. CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALSO IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. WASHED AND DRIED AIRCARE FILTER AND REINSTALLED. CHECKED SPLITS, RETURN 75 SUPPLY 55. SYSTEM IS RUNNING PROPER AT THIS TIME.

Near E Kilarea Ave, Mesa, AZ 85209
Brian S.

Brian S.

In Mesa, AZ: CHECKED ATTIC AIR HANDLER ALL LEVEL AND PROPER. CHECKED SUPPLY AND RETURN DUCT WORK IS SEALED AND LOOKS GOOD. PVC DRAIN LINE INSTALLED AND GLUED. SECONDARY DRAIN PAN IS INSTALLED WITH WET SWITCH. ATTIC IS CLEAN AND EVERYTHING LOOKS GOOD. CHECKED CONDENSER HIGH VOLTAGE IS TIGHT AND IS GOOD. INSULE TUBING IS INSTALLED PROPERLY AND NEW DISCONNECT WITH NEW WHIP LOOKS GOOD INSTALL LOOKS GOOD AND IS RUNNING PROPER. CHARGE IS LOOKING GOOD ALL COMPLETE.

Near S Greenfield Rd, Mesa, AZ 85206
Mesa, AZ - In Mesa, AZ:  CHECKED ATTIC AIR HANDLER ALL LEVEL AND PROPER. CHECKED SUPPLY AND RETURN DUCT WORK IS SEALED AND LOOKS GOOD. PVC DRAIN LINE INSTALLED AND GLUED. SECONDARY DRAIN PAN IS INSTALLED WITH WET SWITCH. ATTIC IS CLEAN AND EVERYTHING  LOOKS GOOD. CHECKED CONDENSER HIGH VOLTAGE IS TIGHT AND IS GOOD. INSULE TUBING IS INSTALLED PROPERLY AND NEW DISCONNECT WITH NEW WHIP LOOKS GOOD INSTALL LOOKS GOOD AND IS RUNNING PROPER. CHARGE IS LOOKING GOOD ALL COMPLETE.
Leonardo G.

Leonardo G.

In Mesa, AZ: UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. REPLACED INTAKE FILTERS AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. HOMEOWNER STATED THERMOSTAT TEMP WOULD GO UP TO 80 DEGREES . FOUND NO ISSUE AF TIME OF SERVICE.

Near E Monte Ave, Mesa, AZ 85209
Mesa, AZ - In Mesa, AZ:  UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. REPLACED INTAKE FILTERS AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. HOMEOWNER STATED THERMOSTAT TEMP WOULD GO UP TO 80 DEGREES . FOUND NO ISSUE AF TIME OF SERVICE.
Tom G.

Tom G.

In Mesa, AZ: Unit 1- bearing in motor has failed. Pump and and basket need to be replaced. Unit 2- pump and basket need to be replaced. Mineral build up for age of system is heavy. Pads need to be replaced. Unit 3- motor is failing. Pump does not work. Float is sticking. Unit 4- needs pump and basket Unit 5- needs pump and basket. New pads needed there is heavy build up. Float will not fully shut off. Unit 6- needs pump and basket. New pads needed there is heavy build up. Ducting for coolers one and two is not far enough down in shop. Listed pricing to extend them four feet down with a triangle. Scissor lift rental priced into bid. There is no drains hooked up to any of the evaporative cooler. Would recommend plumbing into original drains or connecting all to run into roof drains. Completed services for six systems at a local commercial building. Coolers are need of parts before they are functioning properly. Pending approvals.

Near E Coury Ave, Mesa, AZ 85210
Mesa, AZ - In Mesa, AZ:  Unit 1- bearing in motor has failed. Pump and and basket need to be replaced.
Unit 2- pump and basket need to be replaced. Mineral build up for age of system is heavy. Pads need to be replaced.
Unit 3- motor is failing. Pump does not  work. Float is sticking.
Unit 4- needs pump and basket
Unit 5- needs pump and basket. New pads needed there is heavy build up. Float will not fully shut off.
Unit 6- needs pump and basket. New pads needed there is heavy build up.  Ducting for coolers one and two is not far enough down in shop. Listed pricing to extend them four feet down with a triangle. Scissor lift rental priced into bid.  There is no drains hooked up to any of the evaporative cooler. Would recommend plumbing into original drains or connecting all to run into roof drains.
Completed services for six systems at a local commercial building. Coolers are need of parts before they are functioning properly. Pending approvals.
John S.

John S.

Removing a old split system out of a attic and installing a new Goodman system off of E southern ave az

Near Unnamed Road, Mesa, AZ 85206
Mesa, AZ - Removing a old split system out of a attic and installing a new Goodman system off of E southern ave az
Leonardo G.

Leonardo G.

In Mesa, AZ: UPON ARRIVAL NOTICED BATTERIES TO THERMOSTAT WERE LOW. REPLACED BATTERIES. CYCLED UNIT INTO COOLING MODE. REPLACED INTAKE FILTERS AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CHECKED VOLTS AND AMP DRAWS FROM COMPONENTS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. CHECKED START AND RUN CAPACITORS. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN SPEC.

Near N Orangewood Dr, Mesa, AZ 85203
Mesa, AZ - In Mesa, AZ:  UPON ARRIVAL NOTICED BATTERIES TO THERMOSTAT WERE LOW. REPLACED BATTERIES. CYCLED UNIT INTO COOLING MODE. REPLACED INTAKE FILTERS AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CHECKED VOLTS AND AMP DRAWS FROM COMPONENTS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. CHECKED START AND RUN CAPACITORS. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN SPEC.
Brian S.

Brian S.

In Mesa Az installing a new control board under warranty for this Amana. All working proper now.

Near E Decatur St, Mesa, AZ 85205
Mesa, AZ - In Mesa Az installing a new control board under warranty for this Amana. All working proper now.
Brian S.

Brian S.

In Mesa Az servicing a customers system. Checked volt and amp draws. Cleaned and tightened electrical connections. Checked Freon levels. Acid washed outdoor coil and rinsed and changed return filter.

Near Unnamed Road, Mesa, AZ 85206
Mesa, AZ - In Mesa Az servicing a customers system. Checked volt and amp draws. Cleaned and tightened electrical connections. Checked Freon levels. Acid washed outdoor coil and rinsed and changed return filter.
Brian S.

Brian S.

In Mesa Az servicing a customers system. Checked volt and amp draws. Cleaned and tightened electrical connections. Checked Freon levels and pressures. Acid washed outdoor coil and changed return filter.

Near E Lomita Ave, Mesa, AZ 85209
Mesa, AZ - In Mesa Az servicing a customers system. Checked volt and amp draws. Cleaned and tightened electrical connections. Checked Freon levels and pressures. Acid washed outdoor coil and changed return filter.
Brian S.

Brian S.

In Mesa Az quality inspecting a new Amana system we just installed. The job came out perfect and customer is extremely happy. Another awesome job by our install team.

Near S Quinn Cir, Mesa, AZ 85206
Mesa, AZ - In Mesa Az quality inspecting a new Amana system we just installed. The job came out perfect and customer is extremely happy. Another awesome job by our install team.
Mason  C.

Mason C.

Installed new 14 seer 3 ton hp split system

Near S Quinn Cir, Mesa, AZ 85206
Mesa, AZ - Installed new 14 seer 3 ton hp split system
John S.

John S.

Installing a new split system for a residential home right off of Broadway Rd Mesa, AZ

Near E Main St, Mesa, AZ 85205
Mesa, AZ - Installing a new split system for a residential home right off of Broadway Rd Mesa, AZ
Brian S.

Brian S.

Installing a split system in a residential home that includes new whip, thermostat, disconnect box, fuses, as well as a new drain pan and new primary and secondary drain lines in Mesa, Az

Near S Quinn Cir, Mesa, AZ 85206
Mesa, AZ - Installing a split system in a residential home that includes new whip, thermostat, disconnect box, fuses, as well as a new drain pan and new primary and secondary drain lines in Mesa, Az
Brian S.

Brian S.

In Mesa Az servicing a customers 2 systems. Checked volt and amp draws. Cleaned and tightened electrical connections. Checked Freon levels and pressures. Washed out filters and acid washed outdoor coils and rinsed.

Near E Sunland Ave, Mesa, AZ 85208
Mesa, AZ - In Mesa Az servicing a customers 2 systems. Checked volt and amp draws. Cleaned and tightened electrical connections. Checked Freon levels and pressures. Washed out filters and acid washed outdoor coils and rinsed.
Dillon G.

Dillon G.

In Mesa, Az installing a new Amana Split System.

Near E Main St, Mesa, AZ 85205
Mesa, AZ - In Mesa, Az  installing a new Amana Split System.
Tom G.

Tom G.

In Mesa performing a tune up service for an existing customer!

Near E Main St, Mesa, AZ 85213
Mesa, AZ - In Mesa performing a tune up service for an existing customer!
Leonardo G.

Leonardo G.

Performing cooling maintenance on a heat pump 14 seer ICP split system in Mesa Arizona.

Near S Quinn Cir, Mesa, AZ 85206
Mesa, AZ - Performing cooling maintenance on a heat pump 14 seer ICP split system in Mesa Arizona.
Brian S.

Brian S.

In Mesa Az servicing a customers system. Acid washed outdoor coil and rinsed. Checked volt and amp draws. Cleaned and tightened electrical connections. Checked Freon levels and washed out return filter.

Near S Ellsworth Rd, Mesa, AZ 85209
Mesa, AZ - In Mesa Az servicing a customers system. Acid washed outdoor coil and rinsed. Checked volt and amp draws. Cleaned and tightened electrical connections. Checked Freon levels and washed out return filter.
Brian S.

Brian S.

In Mesa Az servicing a customers system. Checked volt and amp draws. Checked Freon levels and pressures. Cleaned and tightened electrical connections changed the return air filters and washed the outdoor coil.

Near E Grandview St, Mesa, AZ 85207
Mesa, AZ - In Mesa Az servicing a customers system. Checked volt and amp draws. Checked Freon levels and pressures. Cleaned and tightened electrical connections changed the return air filters and washed the outdoor coil.
Brian S.

Brian S.

In Mesa servicing a customers Amana system cleaned and tightened the electrical. Changed the filters and inspected volt and amp draws.

Near N Westwood Cir, Mesa, AZ 85201
Mesa, AZ - In Mesa servicing a customers Amana system cleaned and tightened the electrical. Changed the filters and inspected volt and amp draws.