Peoria, AZ Heating and Air Conditioning Services

Morehart Air Conditioning & Heating provides heater and air conditioning repair,  installation and services in Peoria, AZ and surrounding areas.

Check out what some of our customers are saying about Morehart Air Conditioning & Heating  services.

Local Reviews
for Peoria, AZ

Morehart Air Conditioning & Heating Rated 5.0 out of 5 stars based on 4 customer reviews

Map of Peoria, AZ

Great Service




Review of Morehart Air Conditioning & Heating

Tom was on time and professional!


Map of Peoria, AZ

Amazing service!!!




Review of Morehart Air Conditioning & Heating

We had a great experience today having Tom come out and service our units. He was very knowledgeable and professional.


Map of Peoria, AZ

great service




Review of Morehart Air Conditioning & Heating

tech was able to find a problem and show me what was wrong with the part, that he had to replace.


Map of Peoria, AZ

Servoce review




Review of Morehart Air Conditioning & Heating

Tom, service tech, and the support staff were amazing. Tom explained everything, complete with pictures. I prefer to work with family-run businesses whose reputation, work-ethic and value for service are primary consideration. This was AMAZING!


Response from Morehart Air Conditioning & Heating:

Thank you so much for you feed back! We value and appreciate you as our customer!


Tom G.

Tom G.

In Peoria, AZ: DIAGNOSTIC- Upon arrival, found codes in thermostat that reflected the last three days not keeping set temperature from 3-5 pm. Found indoor filter extremely restricted, replaced filter. Inspected indoor coil for build up. At condensing unit, charge is abnormal. 114/456 psig. SLT 104 degrees. Splits at 5 degrees. Added charge to system. Unit level out at 125/460 psig SLT 82 degrees. Splits 58/77. Recommend replacing TXV. In addition, ducting needs to be cleaned and 20x30 grill replaced. Customer has grill taped because it will not stay closed. Finally there are codes room sensor is not communicating. This is most likely due to a dead battery. Customer said he lost where the sensor is and wanted pricing on getting more.

Near W Villa Lindo Dr, Peoria, AZ 85383
Peoria, AZ - In Peoria, AZ:  DIAGNOSTIC-  Upon arrival, found codes in thermostat that reflected the last three days not keeping set temperature from 3-5 pm. Found indoor filter extremely restricted, replaced filter. Inspected indoor coil for build up. At condensing unit, charge is abnormal. 114/456 psig. SLT 104 degrees. Splits at 5 degrees. Added charge to system. Unit level out at 125/460 psig SLT 82 degrees. Splits 58/77. Recommend replacing TXV. In addition, ducting needs to be cleaned and 20x30 grill replaced. Customer has grill taped because it will not stay closed. Finally there are codes room sensor is not communicating. This is most likely due to a dead battery. Customer said he lost where the sensor is and wanted pricing on getting more.
Tom G.

Tom G.

In Peoria, AZ: DIAGNOSTIC- Customer had an issue with temporary hold on thermostat. Walked home and verified supply temperature with customer 55/79. Offered to rework ducting but he wanted to make sure the supply temperatures were right. Service complete.

Near W Sunnyslope Ln, Peoria, AZ 85345
Peoria, AZ - In Peoria, AZ:  DIAGNOSTIC-  Customer had an issue with temporary hold on thermostat. Walked home and verified supply temperature with customer 55/79. Offered to rework ducting but he wanted to make sure the supply temperatures were right. Service complete.
Brian S.

Brian S.

In Peoria, AZ: INSTALLED PARTS- Installed new harness for the mini split. All is working properly and within manufacturer specifications. Customer asked me to check the other mini split; he thought it was warm. Checked Freon. All within manufacturer specifications. Service complete.

Near N 91st Ave, Peoria, AZ 85383
Peoria, AZ - In Peoria, AZ:  INSTALLED PARTS-  Installed new harness for the mini split. All is working properly and within manufacturer specifications. Customer asked me to check the other mini split; he thought it was warm. Checked Freon. All within manufacturer specifications. Service complete.
Leonardo G.

Leonardo G.

In Peoria, AZ: DIAGNOSTIC- Upon arrival, cycled Casita into cooling mode and noticed no air coming out of vents. Thermostat not communicating with dampers. Bypassed zone system. Talked to homeowner about mini split for Casita. Upon departure, unit is working properly and within manufacturer specifications. Service complete.

Near W Calavar Rd, Peoria, AZ 85381
John S.

John S.

Installing a double split system near deer valley rd az

Near W Salter Dr, Peoria, AZ 85382
Peoria, AZ - Installing a double split system near deer valley rd az
Leonardo G.

Leonardo G.

In Peoria, AZ: DIAGNOSTIC- Upon arrival, cycled unit into cooling mode. Opened all dampers to home. Noticed damper to kids room not opening when calling for it. Removed wire to terminal on damper. Damper opened and provided proper air flow to kids room. Upon departure, unit is working properly and within manufacturer specifications. Service complete.

Near W Calavar Rd, Peoria, AZ 85381
Tom G.

Tom G.

In Peoria, AZ: DIAGNOSTIC- Upon arrival, found middle leg 3ph power not distributing through disconnect box. Box was most likely damaged when the wire burnt out. Need to return to repair system when parts come in. Pending approval before ordering parts. Service complete.

Near W Bell Rd, Peoria, AZ 85382
Peoria, AZ - In Peoria, AZ:  DIAGNOSTIC-  Upon arrival, found middle leg 3ph power not distributing through disconnect box. Box was most likely damaged when the wire burnt out. Need to return to repair system when parts come in. Pending approval before ordering parts. Service complete.
Leonardo G.

Leonardo G.

In Peoria, AZ: PREVENTATIVE MAINTENANCE- Upon arrival, cycled units into cooling mode. Took temperature readings from supply and return. At units, cleaned and tightened electrical connections. Checked volts and amp draws from components. Checked start and run capacitors. Also, checked Freon levels with superheat and subcool. Washed and rinsed outdoor coils. Upon departure, units are working properly and within factory specifications.

Near N 81st Ave, Peoria, AZ 85383
Peoria, AZ - In Peoria, AZ:  PREVENTATIVE MAINTENANCE-  Upon arrival, cycled units into cooling mode. Took temperature readings from supply and return. At units, cleaned and tightened electrical connections. Checked volts and amp draws from components. Checked start and run capacitors. Also, checked Freon levels with superheat and subcool. Washed and rinsed outdoor coils. Upon departure, units are working properly and within factory specifications.
Tom G.

Tom G.

In Peoria, AZ: Replaced 45/5 capacitor that was under warranty.

Near N 81st Ave, Peoria, AZ 85383
Peoria, AZ - In Peoria, AZ:  Replaced 45/5 capacitor that was under warranty.
Tom G.

Tom G.

In Peoria, AZ: DIAGNOSTIC- Upon arrival, found high volt to system burnt off of main supply lug. Cut back damaged wiring and spliced in new wire. Tightened all terminal connections. Tested compressor. System working properly upon departure.

Near W Bell Rd, Peoria, AZ 85382
Peoria, AZ - In Peoria, AZ:  DIAGNOSTIC-  Upon arrival, found high volt to system burnt off of main supply lug. Cut back damaged wiring and spliced in new wire. Tightened all terminal connections. Tested compressor. System working properly upon departure.
Brian S.

Brian S.

In Peoria, AZ: Install new warranty control board for Daikin system.

Near N 91st Ave, Peoria, AZ 85383
Tom G.

Tom G.

In Peoria, AZ: Completed quality inspection on new install; system working properly and within manufacturer specifications upon departure.

Near W Sunnyslope Ln, Peoria, AZ 85345
Peoria, AZ - In Peoria, AZ:  Completed quality inspection on new install; system working properly and within manufacturer specifications upon departure.
Brian S.

Brian S.

In Peoria, AZ: Estimate for a new 4 ton package heat pump; roof jack is 45 3/4"; top 26 1/4"; side 2"; high jack side by 5/12 pitch.

Near W Beryl Ave, Peoria, AZ 85345
Peoria, AZ - In Peoria, AZ:  Estimate for a new 4 ton package heat pump; roof jack is 45 3/4"; top 26 1/4"; side 2"; high jack side by 5/12 pitch.
John S.

John S.

Removing a old package unit and replacing it with new carrier

Near W Sunnyslope Ln, Peoria, AZ 85345
Peoria, AZ - Removing a old package unit and replacing it with new carrier
Tom G.

Tom G.

In Peoria, AZ: Morehart AC to install and furnish 4 ton seer Payne package heat pump. System has 10 year parts and compressor warranty. System will include new thermostat, stand for 5/12 pitch, slip over elbow 21.5X38, and drain line. To hook up to existing low volt, high volt, and ducting.

Near W Sunnyslope Ln, Peoria, AZ 85345
Peoria, AZ - In Peoria, AZ:  Morehart AC to install and furnish 4 ton seer Payne package heat pump. System has 10 year parts and compressor warranty. System will include new thermostat, stand for 5/12 pitch, slip over elbow 21.5X38, and drain line. To hook up to existing low volt, high volt, and ducting.
Tom G.

Tom G.

In Peoria, AZ: UPON ARRIVAL SPOKE WITH CUSTOMER SHE SAID HEATING DOES NOT WORK ON SYSTEM DUE TO A LOW VOLTAGE ISSUE. THE THERMOSTAT THAT WAS INSTALLED IS NOT WIRED CORRECTLY. CYCLED SYSTEM INTO COOLING. 410a CHARGE SET TO 144/425 PSIG. 104 AMBIENT. 86 WET BULB. COMPRESSOR RATED AT 17.9 RLA, ACTUAL IS 14.88 RLA. FAN MOTOR RATED AT 1.5 FLA, ACTUAL 1.44 FLA. CAPACITOR 45/5uf TESTING AT 43.4/1.7uf. THIS IS OUT OF 6% TOLERANCE RECOMMEND REPLACEMENT OF CAPACITOR. INSULATION ON LINE SET IS SUN ROTTED AND SHOULD BE REPLACED. SCHRADER CAP IS MISSING FOR HEATING SUCTION LINE PORT. NEXT INSPECTED AIR HANDLER. IN THE ATTIC NEXT TO UNIT THE OLD SECONDARY PAN AND DOORS FROM PREVIOUS SYSTEM WHERE LEFT IN ATTIC. RECOMMEND CLEANING ATTIC FROM INSTALLATION. THERE IS NO RETURN BOX ON THE SYSTEM. THE ORIGINAL SUPPLY PLYNUM WAS USED FOR INSTALLATION. DUCTING IS ORIGINAL TO HOME. BLOWER MOTOR RATED AT 3.12 ACTUAL IS 2.98 FLA, THIS IS MOST LIKELY DUE TO RESTRICTED DUCTING. LOW VOLT IS NOT SEALED GOING INTO

Near W Athens St, Peoria, AZ 85382
Peoria, AZ - In Peoria, AZ:  UPON ARRIVAL SPOKE WITH CUSTOMER SHE SAID HEATING DOES NOT WORK ON SYSTEM DUE TO A LOW VOLTAGE ISSUE. THE THERMOSTAT THAT WAS INSTALLED IS NOT WIRED CORRECTLY. CYCLED SYSTEM INTO COOLING. 410a CHARGE SET TO 144/425 PSIG. 104 AMBIENT. 86 WET BULB. COMPRESSOR RATED AT 17.9 RLA, ACTUAL IS 14.88 RLA. FAN MOTOR RATED AT 1.5 FLA, ACTUAL 1.44 FLA. CAPACITOR 45/5uf TESTING AT 43.4/1.7uf. THIS IS OUT OF 6% TOLERANCE RECOMMEND REPLACEMENT OF CAPACITOR. INSULATION ON LINE SET IS SUN ROTTED AND SHOULD BE REPLACED. SCHRADER CAP IS MISSING FOR HEATING SUCTION LINE PORT. NEXT INSPECTED AIR HANDLER. IN THE ATTIC NEXT TO UNIT THE OLD SECONDARY PAN AND DOORS FROM PREVIOUS SYSTEM WHERE LEFT IN ATTIC. RECOMMEND CLEANING ATTIC FROM INSTALLATION. THERE IS NO RETURN BOX ON THE SYSTEM. THE ORIGINAL SUPPLY PLYNUM WAS USED FOR INSTALLATION. DUCTING IS ORIGINAL TO HOME. BLOWER MOTOR RATED AT 3.12 ACTUAL IS 2.98 FLA, THIS IS MOST LIKELY DUE TO RESTRICTED DUCTING. LOW VOLT IS NOT SEALED GOING INTO
Brian S.

Brian S.

In Peoria, AZ: COOLER #1 44”TALL 48” WIDE COOLER PADS. COOLER #2 44” TALL 48” WIDE COOLER PADS. A/C #6 NEEDS NEW 1/4 HORSE 1075 MOTOR AND 7.5/440 CAP. A/C #9 NEEDS TWO NEW 5/440 CAPACITORS. INSTALLED NEW PADS, MOTOR AND CAPACITORS ALL WORKING PROPER ALL COMPLETE.

Near W Bell Rd, Peoria, AZ 85382
Leonardo G.

Leonardo G.

In Peoria, AZ: Upon arrival, homeowner cycled unit into cooling mode. Let unit cycle for 10-15 minutes. Checked charge on system 58/252 PSI R410-A. Noticed system extremely low on charge and found leak on copper to aluminum joint at condensing coil. Verified leak with soap bubbles. Gave homeowner labor quote on replacing condensing coil. Collected diagnosis, charged, and left condensing unit unplugged at disconnect box.

Near N 79th Dr, Peoria, AZ 85383
Peoria, AZ - In Peoria, AZ:  Upon arrival, homeowner cycled unit into cooling mode. Let unit cycle for 10-15 minutes. Checked charge on system 58/252 PSI R410-A. Noticed system extremely low on charge and found leak on copper to aluminum joint at condensing coil. Verified leak with soap bubbles. Gave homeowner labor quote on replacing condensing coil. Collected diagnosis, charged, and left condensing unit unplugged at disconnect box.
Brian S.

Brian S.

In Peoria, AZ: Cycled system on into cooling mode. Checked volt and amp draws; all in factory specification. Cleaned and tightened electrical connections. Checked Freon levels and pressures; also in factory specification. Acid washed coil and rinsed. Gave customer a new filter for next change out. Checked splits: Return 79, Supply 57. System is running properly at time of service completion.

Near W Larkspur Dr, Peoria, AZ 85381
Peoria, AZ - In Peoria, AZ:  Cycled system on into cooling mode. Checked volt and amp draws; all in factory specification. Cleaned and tightened electrical connections. Checked Freon levels and pressures; also in factory specification. Acid washed coil and rinsed. Gave customer a new filter for next change out. Checked splits: Return 79, Supply 57. System is running properly at time of service completion.
Brian S.

Brian S.

In Peoria, AZ: Cycled system on into cooling mode. Checked volt and amp draws; all in factory specification. Cleaned and tightened electrical connections. Checked Freon levels and pressures. Also within manufacturer specification. Acid washed outdoor coil and rinsed. Changed return air filters and checked splits: Return 76, Supply 56. System is running properly at this time.

Near N 82nd Ln, Peoria, AZ 85382
Peoria, AZ - In Peoria, AZ:  Cycled system on into cooling mode. Checked volt and amp draws; all in factory specification. Cleaned and tightened electrical connections. Checked Freon levels and pressures. Also within manufacturer specification. Acid washed outdoor coil and rinsed. Changed return air filters and checked splits: Return 76, Supply 56. System is running properly at this time.
Brian S.

Brian S.

In Peoria, AZ: Found float on the cooler not shutting off. Installed new float; all working properly at completion of service.

Near N 88th Dr, Peoria, AZ 85382
Peoria, AZ - In Peoria, AZ:  Found float on the cooler not shutting off. Installed new float; all working properly at completion of service.
Leonardo G.

Leonardo G.

In Peoria, AZ: Upon arrival, turned power off to system and removed wires to module. Installed and mounted new module to cabinet. Put wires on terminals. Upon departure, unit is working properly and within manufacturer specifications.

Near W Country Gables Dr, Peoria, AZ 85381
Brian S.

Brian S.

In Peoria, AZ: Install new warranty control board for Daikin system.

Near N 91st Ave, Peoria, AZ 85383
Peoria, AZ - In Peoria, AZ:  Install new warranty control board for Daikin system.
Tom G.

Tom G.

In Peoria, AZ: Replacement of filters for building. On York system, 1 inch filters were installed; replaced with OEM 2 inch filters. On north Carrier unit, filters were stuck in damper. Removed during filter replacement. Service completed.

Near N 91st Ave, Peoria, AZ 85345
Brian S.

Brian S.

In Peoria, AZ: On arrival, found compressor not running. Tested run capacitor 0.0/0.0/440 needs new 45/5/440 capacitor system is under warranty for 2 more years. Charged customer for labor.

Near W St John Rd, Peoria, AZ 85382
Peoria, AZ - In Peoria, AZ:  On arrival, found compressor not running. Tested run capacitor 0.0/0.0/440 needs new 45/5/440 capacitor system is under warranty for 2 more years. Charged customer for labor.
Brian S.

Brian S.

In Peoria, AZ: York system checked; drain pan water had overflowed 2 years ago because of a blocked drain line. Issue was addressed and repaired at that time; drain is properly pitched and working. Completed service on York system.

Near W Dale Ln, Peoria, AZ 85383
Peoria, AZ - In Peoria, AZ:  York system checked; drain pan water had overflowed 2 years ago because of a blocked drain line. Issue was addressed and repaired at that time; drain is properly pitched and working. Completed service on York system.
Brian S.

Brian S.

In Peoria, AZ: On arrival, found system was off; 12 different fault codes. On further inspection, found system low on R410 Freon. Performed a leak search. Outdoor condenser is sealed; no leaks. Received hits by both indoor head systems. Was not able to remove to confirm any leaks; possible leaks on indoor heads or inside line set. Need to return tomorrow with help and pull off head units to check for leaks.

Near N 91st Ave, Peoria, AZ 85383
Peoria, AZ - In Peoria, AZ:  On arrival, found system was off; 12 different fault codes. On further inspection, found system low on R410 Freon. Performed a leak search. Outdoor condenser is sealed; no leaks. Received hits by both indoor head systems. Was not able to remove to confirm any leaks; possible leaks on indoor heads or inside line set. Need to return tomorrow with help and pull off head units to check for leaks.
Tom G.

Tom G.

In Peoria, AZ: Free estimate for new system; pending green sky approval.

Near N 89th Ave, Peoria, AZ 85381
Peoria, AZ - In Peoria, AZ:  Free estimate for new system; pending green sky approval.
Brian S.

Brian S.

In Peoria, AZ: Checked volt and amp draws all in factory specification. Checked Freon; system working very well. System is working proper. Next visit, placement of ISO pads under condenser. Gave pricing for mini split in the bedroom.

Near W Wescott Dr, Peoria, AZ 85382
Peoria, AZ - In Peoria, AZ:  Checked volt and amp draws all in factory specification. Checked Freon; system working very well. System is working proper. Next visit, placement of ISO pads under condenser. Gave pricing for mini split in the bedroom.
Tom G.

Tom G.

In Peoria, AZ: Completed services for two systems in accordance with maintenance checklist. Systems working properly upon departure. Disconnect box #2, the plastic behind the fuses is cracked. This is not causing a mechanical issue but should be replaced. Listed estimate for new box.

Near N 79th Dr, Peoria, AZ 85381
Peoria, AZ - In Peoria, AZ:  Completed services for two systems in accordance with maintenance checklist. Systems working properly upon departure. Disconnect box #2, the plastic behind the fuses is cracked. This is not causing a mechanical issue but should be replaced. Listed estimate for new box.
Brian S.

Brian S.

In Peoria, AZ: COOLER #1 CLEANED OUT WET SECTION. OILED BEARINGS. PADS ARE IN GOOD CONDITION. BELTS ARE PROPER. PUMP IS NEWER AND MOTOR IS RUNNING PROPER. COOLER #2 CLEANED OUT WET SECTION. OILED BEARINGS. PADS ARE GOOD. CLEANED OUT PUMP AND BASKET INSTALLED 2 NEW B-108 BELTS. MOTOR IS IN SPECIFICATION. COOLER #3 CLEANED OUT WET SECTION. OILED BEARINGS. PADS ARE IN GOOD SHAPE. CLEANED OUT PUMP AND BASKET. CLEANED OUT WATER LINES. COOLER NEEDS 2 NEW B108 BELTS. MOTOR IS IN SPECIFICATION. COOLER #4 CLEANED OUT WET SECTION. OILED BEARINGS. CLEANED PUMP AND BASKET. CLEANED OUT WATER LINES. NEED TWO NEW B108 BELTS. MOTOR IS IN SPECIFICATION. COOLER #5 OUT WET SECTION. OILED BEARINGS. CLEANED PUMP AND BASKET. CLEANED OUT WATER LINES. NEED TWO NEW B108 BELTS. MOTOR IS IN SPECIFICATION. SYSTEM #1 RUNNING PROPER SEE COOLING CHECKLIST FOR DETAILS. SYSTEM IS RUNNING PROPER SEE COOLING CHECKLIST FOR DETAILS. EXHAUST FAN MOTOR IS LOCKED UP. NEEDS NEW 1/4 HORSE 1740 RPM SENT QU

Near W Golden Ln, Peoria, AZ 85345
Peoria, AZ - In Peoria, AZ:  COOLER #1 CLEANED OUT WET SECTION. OILED BEARINGS. PADS ARE IN GOOD CONDITION. BELTS ARE PROPER. PUMP IS NEWER AND MOTOR IS RUNNING PROPER.  COOLER #2 CLEANED OUT WET SECTION. OILED BEARINGS. PADS ARE GOOD. CLEANED OUT PUMP AND BASKET INSTALLED 2 NEW B-108 BELTS. MOTOR IS IN SPECIFICATION.  COOLER #3 CLEANED OUT WET SECTION. OILED BEARINGS. PADS ARE IN GOOD SHAPE. CLEANED OUT PUMP AND BASKET. CLEANED OUT WATER LINES. COOLER NEEDS 2 NEW B108 BELTS. MOTOR IS IN SPECIFICATION.  COOLER #4 CLEANED OUT WET SECTION. OILED BEARINGS. CLEANED PUMP AND BASKET. CLEANED OUT WATER LINES. NEED TWO NEW B108 BELTS. MOTOR IS IN SPECIFICATION.  COOLER #5 OUT WET SECTION. OILED BEARINGS. CLEANED PUMP AND BASKET. CLEANED OUT WATER LINES. NEED TWO NEW B108 BELTS. MOTOR IS IN SPECIFICATION.  SYSTEM #1 RUNNING PROPER SEE COOLING CHECKLIST FOR DETAILS.  SYSTEM IS RUNNING PROPER SEE COOLING CHECKLIST FOR DETAILS.  EXHAUST FAN MOTOR IS LOCKED UP. NEEDS NEW 1/4 HORSE 1740 RPM SENT QU
Tom G.

Tom G.

In Peoria, AZ: Completed services in accordance with maintenance checklist. Please monitor condensing fan motors, they are both leaking oil. Systems working properly upon departure.

Near W Escuda Dr, Peoria, AZ 85382
Peoria, AZ - In Peoria, AZ:  Completed services in accordance with maintenance checklist. Please monitor condensing fan motors, they are both leaking oil. Systems working properly upon departure.
Brian S.

Brian S.

In Peoria, AZ: CYCLED DOWN STAIRS SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS, ALL IN FACTORY SPECIFICATION. CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALSO IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR RATINGS AND DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. CHANGED RETURN AIR FILTER AND CHECKED SPLITS, RETURN 75 SUPPLY 56. SYSTEM NEEDS NEW 45/5/440 CAPACITOR. INSTALLED NEW RUN CAPACITOR ALL WORKING PROPER. CYCLED UP STAIRS SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS, ALL IN FACTORY SPECIFICATION. CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALSO IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR RATINGS AND DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. CHANGED RETURN AIR FILTER AND CHECKED SPLITS, RETURN 75 SUPPLY 55.SYSTEM IS NEWER AND RUNNING PROPER AT THIS TIME.

Near W Lariat Ln, Peoria, AZ 85383
Peoria, AZ - In Peoria, AZ:  CYCLED DOWN STAIRS SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS, ALL IN FACTORY SPECIFICATION. CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALSO IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR RATINGS AND DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. CHANGED RETURN AIR FILTER AND CHECKED SPLITS, RETURN 75 SUPPLY 56. SYSTEM NEEDS NEW 45/5/440 CAPACITOR. INSTALLED NEW RUN CAPACITOR ALL WORKING PROPER.  CYCLED UP STAIRS SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS, ALL IN FACTORY SPECIFICATION. CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALSO IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR RATINGS AND DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. CHANGED RETURN AIR FILTER AND CHECKED SPLITS, RETURN 75 SUPPLY 55.SYSTEM IS NEWER AND RUNNING PROPER AT THIS TIME.
Brian S.

Brian S.

In Peoria, AZ: CYCLED UPSTAIRS SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS, ALL IN FACTORY SPECIFICATION. CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALSO IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR RATINGS AND DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. CHANGED RETURN AIR FILTER AND CHECKED SPLITS, RETURN 80 SUPPLY 60. SYSTEM IS RUNNING PROPER AT THIS TIME. CYCLED DOWN STAIRS SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS, ALL IN FACTORY SPECIFICATION. CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALSO IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR RATINGS AND DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. CHANGED RETURN AIR FILTER AND CHECKED SPLITS, RETURN 77 SUPPLY 57. RECOMMEND NEW 45/5/440 CAPACITOR. INSTALLED NEW RUN CAPACITOR UNDER WARRANTY.

Near N 102nd Dr, Peoria, AZ 85383
Peoria, AZ - In Peoria, AZ:  CYCLED UPSTAIRS SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS, ALL IN FACTORY SPECIFICATION. CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALSO IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR RATINGS AND DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. CHANGED RETURN AIR FILTER AND CHECKED SPLITS, RETURN 80 SUPPLY 60. SYSTEM IS RUNNING PROPER AT THIS TIME.  CYCLED DOWN STAIRS SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS, ALL IN FACTORY SPECIFICATION. CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALSO IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR RATINGS AND DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. CHANGED RETURN AIR FILTER AND CHECKED SPLITS, RETURN 77 SUPPLY 57. RECOMMEND NEW 45/5/440 CAPACITOR. INSTALLED NEW RUN CAPACITOR UNDER WARRANTY.
Brian S.

Brian S.

In Peoria, AZ: Cycled system on in cooling. Checked volt and amp draws, and all were within factory specs. Cleaned and tightened electrical connections. Checked Freon levels and pressures, also in factory specs. Acid washed outdoor coil and rinsed. Recommend new 45/5/440 capacitor. Service completed.

Near W Yucca St, Peoria, AZ 85345
Peoria, AZ - In Peoria, AZ:  Cycled system on in cooling. Checked volt and amp draws, and all were within factory specs. Cleaned and tightened electrical connections. Checked Freon levels and pressures, also in factory specs. Acid washed outdoor coil and rinsed. Recommend new 45/5/440 capacitor. Service completed.
Brian S.

Brian S.

In Peoria, AZ: On arrival, found system low on R310A refrigerant. Need to do a leak search. Performed a leak search and found indoor coil leaking oil in the pan and got 3 hits there. Needs new indoor coil. Customer stated that system has warranty. Need to call Lennox on Monday for warranty and part availability.

Near N Makena Pl, Peoria, AZ 85383
Peoria, AZ - In Peoria, AZ:  On arrival, found system low on R310A refrigerant. Need to do a leak search. Performed a leak search and found indoor coil leaking oil in the pan and got 3 hits there. Needs new indoor coil. Customer stated that system has warranty. Need to call Lennox on Monday for warranty and part availability.
Tom G.

Tom G.

In Peoria, AZ: Upon arrival found 60/5 capacitor swollen preventing system from engaging. Replaced part and cycled system. Compressor 21.2/18.36 RLA. Fan 1.4/ 1.19 FLA. System working properly upon departure.

Near W Cinnabar Ave, Peoria, AZ 85345
Peoria, AZ - In Peoria, AZ:  Upon arrival found 60/5 capacitor swollen preventing system from engaging. Replaced part and cycled system. Compressor 21.2/18.36 RLA. Fan 1.4/ 1.19 FLA. System working properly upon departure.
Tom G.

Tom G.

In Peoria, AZ: Upon arrival, inspected West 6500 CFM cooler for detail shop. They are concerned that during the heat of the day, the cooler isn't keeping up. Recommend replacing pads and adding a basket to pump. Overall though, the units are too small for the space and will not function properly with the bay doors open. Explained this to the tech at time of service. Another employee stopped me to look at cooler on new roof SW side. Again, pads to unit are in poor shape. Recommend replacing pads.

Near N 88th Dr, Peoria, AZ 85382
Leonardo G.

Leonardo G.

In Peoria, AZ: UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. WASHED AND RINSED OUTDOOR COILS. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECS.

Near N 68th Dr, Peoria, AZ 85383
Peoria, AZ - In Peoria, AZ:  UPON ARRIVAL CYCLED UNIT INTO COOLING MODE.  TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. WASHED AND RINSED OUTDOOR COILS. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECS.
Leonardo G.

Leonardo G.

In Peoria, AZ: Gave homeowner an estimate on replacing existing duct run to existing cans and registers, as well as blowing 16 inches of R30 insulation into entire attic space. Adding a 14 inch return to master bedroom with a 20X20 return grill. Pending approval from homeowner.

Near W Seldon Ln, Peoria, AZ 85345
Brian S.

Brian S.

In Peoria, AZ: Installed new blower rod, pulley wheel, and two new Y bearings; readjusted wheel. All working properly and service complete.

Near W Daley Ln, Peoria, AZ 85383
Leonardo G.

Leonardo G.

In Peoria, AZ: Upon arrival, cycled unit into cooling mode. Replaced intake filters and took temperature readings from supply and return. At unit, checked volts and amp draws from components. Cleaned and tightened electrical connections. Washed and rinsed outdoor coils. Checked freon levels with super heat and subcool. Upon departure, unit is working properly and within manufacturer specs.

Near W Mary Ann Dr, Peoria, AZ 85382
Peoria, AZ - In Peoria, AZ:  Upon arrival, cycled unit into cooling mode. Replaced intake filters and took temperature readings from supply and return. At unit, checked volts and amp draws from components. Cleaned and tightened electrical connections. Washed and rinsed outdoor coils. Checked freon levels with super heat and subcool. Upon departure, unit is working properly and within manufacturer specs.
Leonardo G.

Leonardo G.

In Peoria, AZ: Upon arrival, cycled unit into cooling mode. Took temperature readings from supply and return. At the outdoor unit, cleaned and tightened electrical connections. Took volts and amp draws. Checked freon levels with super heat and subcool. Washed and rinsed coils. Upon departure, unit working properly and within manufacturer specs. Replaced capacitor under parts and labor warranty.

Near W Harmony Ln, Peoria, AZ 85382
Peoria, AZ - In Peoria, AZ:  Upon arrival, cycled unit into cooling mode. Took temperature readings from supply and return. At the outdoor unit, cleaned and tightened electrical connections. Took volts and amp draws. Checked freon levels with super heat and subcool. Washed and rinsed coils. Upon departure, unit working properly and within manufacturer specs. Replaced capacitor under parts and labor warranty.
Leonardo G.

Leonardo G.

In Peoria, AZ: Upon arrival, cycled unit into cooling mode. Took temperature readings from supply and return. At unit, cleaned and tightened electrical connections. Took volts and amp draws from components. Checked freon levels with super heat and subcool. Checked run and start capacitor. Washed and rinsed outdoor coils. Replaced capacitor under parts and labor warranty.

Near N 98th Ln, Peoria, AZ 85382
Peoria, AZ - In Peoria, AZ:  Upon arrival, cycled unit into cooling mode. Took temperature readings from supply and return. At unit, cleaned and tightened electrical connections. Took volts and amp draws from components. Checked freon levels with super heat and subcool. Checked run and start capacitor. Washed and rinsed outdoor coils. Replaced capacitor under parts and labor warranty.
Brian S.

Brian S.

In Peoria, AZ: Primary blower center rod broke in half. Need to order new center rod, 2 new Y bearing kits, and blower pulley. Rod is 24" long pipe. 12" pulley wheel Y bearings for aerocool trophy series TH6801C. Picked up parts from Fergusen. Need to return to install.

Near W Daley Ln, Peoria, AZ 85383
Peoria, AZ - In Peoria, AZ:  Primary blower center rod broke in half. Need to order new center rod, 2 new Y bearing kits, and blower pulley. Rod is 24" long pipe. 12" pulley wheel Y bearings for aerocool trophy series TH6801C. Picked up parts from Fergusen. Need to return to install.
Brian S.

Brian S.

In Peoria, AZ: ON ARRIVAL FOUND SYSTEM OFF ON LOCKOUT CODE 4. CHECKED RUN CAPACITOR ALL IN FACTORY SPECIFICATION. CHECKED LINE VOLTAGE COMING IN ALSO GOOD TESTED COMPRESSOR WITH MEGA OHM TESTER ALL GREEN. CHECKED FREON LEVELS ALL LOOKING PERFECT. POSSIBLE LOW LINE VOLTAGE MIGHT NEED TO CALL THE ELECTRICIAN IF IT GIVES A CODE 4 AGAIN.

Near N 91st Ave, Peoria, AZ 85383
Brian S.

Brian S.

In Peoria, AZ: CHECKED STAND AND ELBOW BOTH INSTALLED PROPERLY AND SEALED. CHECKED DISCONNECT AND WHIP, INSTALLED AND TIGHT WITH FUSES. PVC DRAIN LINE RAN OFF ROOF AND GLUED. SYSTEM IS LEVEL AND SEALED. CYCLED SYSTEM ON IN COOLING, ALL WORKING PROPER. THERMOSTAT IS TIGHT AND CLEAN. INSTALL LOOKS GOOD AND IS WORKING PROPER.

Near N 78th Dr, Peoria, AZ 85381
Peoria, AZ - In Peoria, AZ:  CHECKED STAND AND ELBOW BOTH INSTALLED PROPERLY AND SEALED. CHECKED DISCONNECT AND WHIP, INSTALLED AND TIGHT WITH FUSES. PVC DRAIN LINE RAN OFF ROOF AND GLUED. SYSTEM IS LEVEL AND SEALED. CYCLED SYSTEM ON IN COOLING, ALL WORKING PROPER. THERMOSTAT IS TIGHT AND CLEAN. INSTALL LOOKS GOOD AND IS WORKING PROPER.
Brian S.

Brian S.

In Peoria, AZ: Pump was not working properly. Installed new pump, now water is soaking the pads much better. Line kept clogging up; most likely the reason the pump was failing.

Near W Bell Rd, Peoria, AZ 85382
Tom G.

Tom G.

In Peoria, AZ: Upon arrival found unit 1 pump is bad and float is adjusted to not let water into tray. Set float and replaced pump. Cleared distribution line. System two distribution line is clogged. Cleared line. Coolers working properly upon departure. Recommend replacement pads.

Near N 91st Ave, Peoria, AZ 85345
Leonardo G.

Leonardo G.

In Peoria, AZ: Upon arrival, cycled unit into cooling mode. Left homeowner with intake filters and took temperature readings from supply and return. At unit, cleaned and tightened electrical connections. Took volt and amp draws from components. Checked run and start capacitors. Checked freon levels with super heat and subcool. Washed and rinsed outdoor coils. Upon departure, Lennox unit was working properly and within manufacturer specifications.

Near N 68th Dr, Peoria, AZ 85383
Peoria, AZ - In Peoria, AZ:  Upon arrival, cycled unit into cooling mode. Left homeowner with intake filters and took temperature readings from supply and return. At unit, cleaned and tightened electrical connections. Took volt and amp draws from components. Checked run and start capacitors. Checked freon levels with super heat and subcool. Washed and rinsed outdoor coils. Upon departure, Lennox unit was working properly and within manufacturer specifications.