Exceptional Service and Professionalism




Review of Morehart Air Conditioning & Heating


Map of Phoenix, AZ

Friendly and Profesional




Review of Morehart Air Conditioning & Heating


Map of Phoenix, AZ

GDB




Review of Morehart Air Conditioning & Heating

Tom always does a nice job and keeps track of all three units to make sure they are up and ready for the summer.


Map of Phoenix, AZ

Leo did a great job! First of all he arrived a few minutes early, which was wonderful considering my house was not getting any cooler. Second, he diag




Review of Morehart Air Conditioning & Heating


Map of Phoenix, AZ

Great Service and Fast Response




Review of Morehart Air Conditioning & Heating


Map of Phoenix, AZ

Excellent customer service!




Review of Morehart Air Conditioning & Heating

Called regarding the evaporated cooler recently installed and he came out that day.


Map of Phoenix, AZ

Great service




Review of Morehart Air Conditioning & Heating

The tech was very prompt. He was knowledgeable and completed the cooler service quickly. The tech pointed out the need for a new belt and other minor adjustments. I was unaware of the need for belt replacement but by changing it out, I got better air flow. I was very satisfied with his skill.


Map of Phoenix, AZ

Professional service at a very reasonable price




Review of Morehart Air Conditioning & Heating


Map of Phoenix, AZ

AC humidity issues




Review of Morehart Air Conditioning & Heating


Map of Phoenix, AZ

Great service. Brian was very informative.




Review of Morehart Air Conditioning & Heating


Leonardo G.

Leonardo G.

In Phoenix, AZ: UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. LEFT HOMEOWNER WITH INTAKE FILTERS AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. WASHED AND RINSED OUTDOOR COILS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. CHECKED RUN AND START CAPACITOR. INSTALLED ECO BEE HOMEOWNER SUPPLIED . TO RETURN AND PERFORM DUCT CLEANING TO ALL REGISTERS AND ALL DUCT WORK . UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECS.

Near E Fellars Dr, Phoenix, AZ 85022
Phoenix, AZ - In Phoenix, AZ:  UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. LEFT HOMEOWNER WITH INTAKE FILTERS AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. WASHED AND RINSED OUTDOOR COILS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. CHECKED RUN AND START CAPACITOR. INSTALLED ECO BEE HOMEOWNER SUPPLIED . TO RETURN AND PERFORM DUCT CLEANING TO ALL REGISTERS AND ALL DUCT WORK . UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECS.
Brian S.

Brian S.

In Phoenix, AZ: CYCLED DOWN STAIRS SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS, ALL IN FACTORY SPECIFICATION. CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALSO IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. CHANGED RETURN AIR FILTERS AND CHECKED SPLITS, RETURN 71 SUPPLY 51. RECOMMEND NEW 70/5/440 CAPACITOR. CYCLED UP STAIRS SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS, ALL IN FACTORY SPECIFICATION. CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALSO IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. CHANGED RETURN AIR FILTERS AND CHECKED SPLITS, RETURN 70 SUPPLY 49. RECOMMEND 35/5/440 RUN CAPACITOR. CUSTOMER STATED THERE IS WARRANTY ON THE SYSTEMS CALLED SIGLER BOTH ARE COVERED UNDER PARTS WARRANTY IN TILL JUNE OF 2021. WARRANTIED OUT BOTH RUN CAPACITORS UNDER WARRANTY.

Near S 41st St, Phoenix, AZ 85044
Phoenix, AZ - In Phoenix, AZ:  CYCLED DOWN STAIRS SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS, ALL IN FACTORY SPECIFICATION. CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALSO IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. CHANGED RETURN AIR FILTERS AND CHECKED SPLITS, RETURN 71 SUPPLY 51. RECOMMEND NEW 70/5/440 CAPACITOR.

CYCLED UP STAIRS SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS, ALL IN FACTORY SPECIFICATION. CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALSO IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. CHANGED RETURN AIR FILTERS AND CHECKED SPLITS, RETURN 70 SUPPLY 49. RECOMMEND 35/5/440 RUN CAPACITOR. CUSTOMER STATED THERE IS WARRANTY ON THE SYSTEMS CALLED SIGLER BOTH ARE COVERED UNDER PARTS WARRANTY IN TILL  JUNE OF 2021. WARRANTIED OUT BOTH RUN CAPACITORS UNDER WARRANTY.
Tom G.

Tom G.

In Phoenix, AZ: Installed pads, tested water flow. Cleaned up work area after repair.

Near N 34th Ave, Phoenix, AZ 85027
Leonardo G.

Leonardo G.

In Phoenix, AZ: Upon arrival, found water spraying out of water supply line. After inspecting, found hairline crack around copper line mear compression fitting. Cut the copper back and put new compression fitting and new nut. Upon departure, no more leak is present.

Near S 19th Pl, Phoenix, AZ 85040
Phoenix, AZ - In Phoenix, AZ:  Upon arrival, found water spraying out of water supply line. After inspecting, found hairline crack around copper line mear compression fitting. Cut the copper back and put new compression fitting and new nut. Upon departure, no more leak is present.
Tom G.

Tom G.

In Phoenix, AZ: Customer showed me noise when unit cycles off. The noise is the refrigerant being released when cycling. System is a r22 Payne condensor connected to a much older trane air handler, recommended replacement of system.

Near S 14th Way, Phoenix, AZ 85048
Tom G.

Tom G.

In Phoenix, AZ: Upon arrival found thermostat not mounted on wall. Resecured to wall. Cycled system. Fan motor is turning on/off. Common wire is burnt off of contactor. Low volt wire is sun rotted and needs replaced. Contactor is heavily burnt and pitted. Recommend replacing motor, capacitor, contactor, and repairing wiring. Customer declined repairs and will get back to us.

Near W Nicolet Ave, Phoenix, AZ 85021
Phoenix, AZ - In Phoenix, AZ:  Upon arrival found thermostat not mounted on wall. Resecured to wall. Cycled system. Fan motor is turning on/off. Common wire is burnt off of contactor. Low volt wire is sun rotted and needs replaced. Contactor is heavily burnt and pitted. Recommend replacing motor, capacitor, contactor, and repairing wiring. Customer declined repairs and will get back to us.
Brian S.

Brian S.

In Phoenix, AZ: FOUND 115 VOLT PUMP ON THE COOLER LOCKED UP REPLACED PUMP ALL WORKING PROPERLY.

Near W Monona Dr, Phoenix, AZ 85027
Phoenix, AZ - In Phoenix, AZ:  FOUND 115 VOLT PUMP ON THE COOLER LOCKED UP REPLACED PUMP ALL WORKING PROPERLY.
Tom G.

Tom G.

In Phoenix, AZ: Completed service in accordance with maintenance checklist. Please refer to list for photos and ratings. System working properly upon departure.

Near E Shady Spring Trail, Phoenix, AZ 85024
Tom G.

Tom G.

In Phoenix, AZ: Completed service in accordance with maintenance checklist. Please refer to list for photos and ratings. Systems working properly upon departure.

Near E Morten Ave, Phoenix, AZ 85020
Phoenix, AZ - In Phoenix, AZ:  Completed service in accordance with maintenance checklist. Please refer to list for photos and ratings. Systems working properly upon departure.
Tom G.

Tom G.

In Phoenix, AZ: Completed service in accordance with maintenance checklist. Please refer to list for photos and ratings. System working properly upon departure.

Near N 23rd Ave, Phoenix, AZ 85023
Phoenix, AZ - In Phoenix, AZ:  Completed service in accordance with maintenance checklist. Please refer to list for photos and ratings. System working properly upon departure.
Leonardo G.

Leonardo G.

In Phoenix, AZ: UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. LEFT HOMEOWNER WITH INTAKE FILTER AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS. CHECKED START AND RUN CAPACITORS . WASHED AND RINSED OUTDOOR COILS. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.

Near S 14th Pl, Phoenix, AZ 85048
Phoenix, AZ - In Phoenix, AZ:  UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. LEFT HOMEOWNER WITH INTAKE FILTER AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS. CHECKED START AND RUN CAPACITORS . WASHED AND RINSED OUTDOOR COILS. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.
Leonardo G.

Leonardo G.

In Phoenix, AZ: UPON ARRIVAL CYCLED UNITS INTO COOLING MODE. REPLACED INTAKE FILTER AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS z TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. CHECKED START AND RUN CAPACITORS AND WASHED AND RINSED OUTDOOR COILS. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.

Near Tanglewood Trail, Phoenix, AZ 85085
Phoenix, AZ - In Phoenix, AZ:  UPON ARRIVAL CYCLED UNITS INTO COOLING MODE. REPLACED INTAKE FILTER AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS z TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. CHECKED START AND RUN CAPACITORS AND WASHED AND RINSED OUTDOOR COILS. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.
Leonardo G.

Leonardo G.

In Phoenix, AZ: SERVICE COMPLETED ON GAS PACKAGE SYSTEM. UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. REPLACED 16x20 INTAKE FILTER. TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP READINGS FROM COMPONENTS. CHECKED FREON LEVELS AND CAPACITORS. CLEANED AND WASHED CONDENSING COILS. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.

Near E Montecito Ave, Phoenix, AZ 85016
Phoenix, AZ - In Phoenix, AZ:  SERVICE COMPLETED ON GAS PACKAGE SYSTEM. UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. REPLACED 16x20 INTAKE FILTER. TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP READINGS FROM COMPONENTS. CHECKED FREON LEVELS AND CAPACITORS. CLEANED AND WASHED CONDENSING COILS. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.
Leonardo G.

Leonardo G.

In Phoenix, AZ: RETURNED AND RE LEVELED COIL FOR A DOWNWARD SLOPE . TO PREVENT MOISTURE TO BUILD UP AND CAUSING HIGH HUMIDITY IN HOME . UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.

Near W Cavalry Dr, Phoenix, AZ 85086
Phoenix, AZ - In Phoenix, AZ:  RETURNED AND RE LEVELED COIL FOR A DOWNWARD SLOPE . TO PREVENT MOISTURE TO BUILD UP AND CAUSING HIGH HUMIDITY IN HOME . UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.
Leonardo G.

Leonardo G.

In Phoenix, AZ: UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. NOTICED WATER LINE LOOSE AND SPRAYING WATER OFF ROOF . PERFORMED TUNE UP ON EVAP COOLER . PLEASE REFER TO CHECKLIST FOR FURTHER DETAILS AND INFORMATION. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.

Near S 19th Pl, Phoenix, AZ 85040
Phoenix, AZ - In Phoenix, AZ:  UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. NOTICED WATER LINE LOOSE AND SPRAYING WATER OFF ROOF . PERFORMED TUNE UP ON EVAP COOLER . PLEASE REFER TO CHECKLIST FOR FURTHER DETAILS AND INFORMATION. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.
Leonardo G.

Leonardo G.

In Phoenix, AZ: UPON INSTALLING CAPACITOR PREVIOUS DAY INSTALLED WIRING BACKWARDS. TODAY REPLACED WIRING TO CORRECT TERMINALS. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN SPEC.

Near W Lacewood Pl, Phoenix, AZ 85045
Brian S.

Brian S.

In Phoenix, AZ: CHECKED UP STAIRS AND DOWN STAIRS CONDENSERS TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON ALL IN FACTORY SPECIFICATION. INSULE TUBING INSTALLED AND PROPER. CHECKED ATTIC FURNACE SUPPLY AND RETURN SEALED TXV NOT LEAKING FLUE PIPING LOOKS GOOD GAS IS SEALED. SECONDARY DRAIN PAN IS INSTALLED WITH WET SWITCH BOTH SYSTEMS LOOK REALLY GOOD COMPLETED ON QUALITY INSPECTION.

Near W Spur Dr, Phoenix, AZ 85083
Tom G.

Tom G.

In Phoenix, AZ: Completed service in accordance with maintenance checklist. Please refer to list for photos and ratings. System working properly upon departure.

Near E Laurel Ln, Phoenix, AZ 85028
Brian S.

Brian S.

In Phoenix, AZ: CHECKED ATTIC AIR HANDLER HIGH VOLT LOOKS GOOD LINESET IS SEALED WITH INSULE TUBING TXV IS INSTALLED AND PROPER. SECONDARY DRAIN PAN IS INSTALLED WITH WET SWITCH. LOW VOLT HAS CONNECTOR AND LOOKS CLEAN. AIR HANDLER IS LEVEL. AIR HANDLER LOOKS REALLY GOOD. CHECKED CHARGE ON SYSTEM ALL LOOKING GOOD NO SIGNS OF LEAKS.

Near E Circle Mountain Rd, Phoenix, AZ 85087
Brian S.

Brian S.

In Phoenix, AZ: CYCLED SYSTEM ON IN COOLING. CHECKED VOLT AND AMP DRAWS, ALL IN FACTORY SPECIFICATION. CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS AND PRESSURES, ALSO IN FACTORY SPECIFICATION. (SEE COOLING CHECKLIST FOR DETAILS). ACID WASHED OUTDOOR COIL AND RINSED. CHANGED RETURN AIR FILTER AND CHECKED SPLITS, RETURN 76 SUPPLY 56. SYSTEM IS RUNNING PROPER AT THIS TIME.

Near W Crocus Dr, Phoenix, AZ 85053
Tom G.

Tom G.

In Phoenix, AZ: Completed service in accordance with maintenance checklist. Please refer to list for photos and ratings. Systems working properly upon departure.

Near N 44th Dr, Phoenix, AZ 85087
Tom G.

Tom G.

In Phoenix, AZ: Completed service in accordance with maintenance checklist. Please refer to list for photos and ratings. Service completed.

Near N 32nd St, Phoenix, AZ 85050
Tom G.

Tom G.

In Phoenix, AZ: Completed service in accordance with maintenance checklist. Please refer to list for photos and ratings. System working properly upon departure.

Near E Melinda Ln, Phoenix, AZ 85050
Tom G.

Tom G.

In Phoenix, AZ: MOREHART AC TO INSTALL AND FURNISH 5 TON PACKAGE HEAT PUMP SYSTEM. TO INCLUDE NEW DISCONNECT, WHIP KIT, DRAIN LINE, ELBOW 39.5/21.5/2.5, STAND 4/12, ECOBEE THERMOSTAT, AND ISO PADS. TO HOOK UP TO EXISTING LOW VOLT, HIGH VOLT, AND DUCTING. PRICE COVERS TAX, INSTALLATION, CRANE, AND REMOVAL OF EXISTING EQUIPMENT. Installation set for Wednesday with a 8-10am arrrival. Job financed. Last name needs to be updated.

Near E Charter Oak Rd, Phoenix, AZ 85032
Phoenix, AZ - In Phoenix, AZ:  MOREHART AC TO INSTALL AND FURNISH 5 TON PACKAGE HEAT PUMP SYSTEM. TO INCLUDE NEW DISCONNECT, WHIP KIT, DRAIN LINE, ELBOW 39.5/21.5/2.5, STAND 4/12, ECOBEE THERMOSTAT, AND ISO PADS. TO HOOK UP TO EXISTING LOW VOLT, HIGH VOLT, AND DUCTING. PRICE COVERS TAX, INSTALLATION, CRANE, AND REMOVAL OF EXISTING EQUIPMENT.
Installation set for Wednesday with a 8-10am arrrival. Job financed.
Last name needs to be updated.
Leonardo G.

Leonardo G.

In Phoenix, AZ: UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. LEFT HOMEOWNER WITH INTAKE FILTERS AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. CHECKED START AND RUN CAPACITORS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. WASHED AND RINSED OUTDOOR COILS. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.

Near N 7th Pl, Phoenix, AZ 85024
Phoenix, AZ - In Phoenix, AZ:  UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. LEFT HOMEOWNER WITH INTAKE FILTERS AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. CHECKED START AND RUN CAPACITORS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. WASHED AND RINSED OUTDOOR COILS. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.
Leonardo G.

Leonardo G.

In Phoenix, AZ: UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. REPLACED INTAKE FILTERS AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. CHECKED RUN AND START CAPACITORS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN SPEC. RECOMMEND UPGRADING HVAC EQUIPMENT.

Near N 28th Dr, Phoenix, AZ 85029
Tom G.

Tom G.

In Phoenix, AZ: Customer said unit is not working and it is very loud. Noise issue- return grill is rattling during operation. Recommend new return grill/ iso pads/ shim for grill if not replaced. Unit not working - condensing coil is leaking. Contacted distributor.

Near E Vista Bonita Dr, Phoenix, AZ 85024
Leonardo G.

Leonardo G.

In Phoenix, AZ: UPON ARRIVAL CYCLED UNIT INTO HEATING MODE. REPLACED 18x30 INTAKE FILTERS AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN SPEC.

Near N Surrey Cir, Phoenix, AZ 85029
Phoenix, AZ - In Phoenix, AZ:  UPON ARRIVAL CYCLED UNIT INTO HEATING MODE. REPLACED 18x30 INTAKE FILTERS AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN SPEC.
Brian S.

Brian S.

In Phoenix, AZ: ON ARRIVAL FOUND SYSTEM LOW ON REFRIGERANT LEO PUT FREON LAST TIME CHARGED SYSTEM WITH R410A AND PERFORMED A LEAK SEARCH. FOUND LEAK ON THE INDOOR COIL NEED TO CALL YORK ON MONDAY TO FIND OUT ABOUT WARRANTY AND AVAILABILITY ADDED TWO POUNDS OF R410A FREON FOR NOW. U.S AIR HAS COIL IN STOCK DOWNTOWN LOCATION.

Near W Portland St, Phoenix, AZ 85003
Phoenix, AZ - In Phoenix, AZ:  ON ARRIVAL FOUND SYSTEM LOW ON REFRIGERANT LEO PUT FREON LAST TIME CHARGED SYSTEM WITH R410A AND PERFORMED A LEAK SEARCH. FOUND LEAK ON THE INDOOR COIL NEED TO CALL YORK ON MONDAY TO FIND OUT ABOUT WARRANTY AND AVAILABILITY ADDED TWO POUNDS OF R410A FREON FOR NOW. U.S AIR HAS COIL IN STOCK DOWNTOWN LOCATION.
Leonardo G.

Leonardo G.

In Phoenix, AZ: UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. HOMEOWNER DECLINED CHANGED FILTER. TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. FOUND COIL UNLEVELED CAUSING WATER TO STAY IN THERE CAUSING HUMIDITY. RECOMMEND RETURNING TO LEVEL. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.

Near W Cavalry Dr, Phoenix, AZ 85086
Phoenix, AZ - In Phoenix, AZ:  UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. HOMEOWNER DECLINED CHANGED FILTER. TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. FOUND COIL UNLEVELED CAUSING WATER TO STAY IN THERE CAUSING HUMIDITY. RECOMMEND RETURNING TO LEVEL. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.
Brian S.

Brian S.

In Phoenix, AZ: CHECKED SYSTEM PANCAKE LOOKS VERY GOOD FOUND DRAIN PAN NOT INSTALLED FAR ENOUGH BACK SO DRAIN HOLES ARE DRIPPING ONTO THE RETURN GRILL NEED TO MOVE PAN BACK 1-2” AND REDO PVC AND MAKE ANOTHER CATCH PAN FOR THE LEFT SIDE OF THE SYSTEM. CONDENSER LOOKS GOOD FREON LEVELS ARE GOOD. INSTALLERS TO RETURN TODAY IN THE AFTERNOON AND MOVE DRAIN PAN IN THE RIGHT POSITION.

Near N 20th St, Phoenix, AZ 85016
Phoenix, AZ - In Phoenix, AZ:  CHECKED SYSTEM PANCAKE LOOKS VERY GOOD FOUND DRAIN PAN NOT INSTALLED FAR ENOUGH BACK SO DRAIN HOLES ARE DRIPPING ONTO THE RETURN GRILL NEED TO MOVE PAN BACK 1-2” AND REDO PVC AND MAKE ANOTHER CATCH PAN FOR THE LEFT SIDE OF THE SYSTEM. CONDENSER LOOKS GOOD FREON LEVELS ARE GOOD. INSTALLERS TO RETURN TODAY IN THE AFTERNOON AND MOVE DRAIN PAN IN THE RIGHT POSITION.
Brian S.

Brian S.

In Phoenix, AZ: INSTALLED NEW PRO SERIES PADS ALL WORKING PROPER ALL COMPLETE.

Near W Purdue Ave, Phoenix, AZ 85051
Brian S.

Brian S.

In Phoenix, AZ: COOLER #1 NEEDS WET SECTION PRESSURE WASH CLEAN OUT. NEEDS NEW A48 BELT, NEEDS NEW 3/8 FLOAT, NEEDS NEW PADS FOR SERIAL #25076. AND NEEDS NEW UMP PUMP AS WELL. WET SECTION IS RUSTED BADLY. COOLER #2 WET SECTION NEEDS PRESSURE WASH CLEAN OUT. NEEDS NEW 3/8 FLOAT. NEEDS NEW A48 BELT AND NEEDS NEW PADS FOR SERIAL #25071. PUMP IS WORKING, WET SECTION IS VERY RUSTED OUT. COOLER #3. NEEDS NEW UMP PADS FOR SERIAL #25070. NEEDS NEW A48 BELT AND NEW A48 BELT AND WET SECTION PRESSURE WASH CLEAN OUT. WET SECTION IS VERY RUSTED. COOLER #4 NEEDS NEW A48 BELT. NEW UMP PADS FOR SERIAL#25072. AND LIGHT WET SECTION CLEAN OUT. COOLER #5 NEEDS NEW 3/8 FLOAT. NEED NEW 3/8 COPPER LINE. NEED TO PRESSURE WASH WET SECTION AND NEW 1/2 WATER SHUT OFF VALVE AND NEW UMP PUMP. PADS ARE IN GOOD CONDITION. COOLER #6 NEEDS A NEW UMP PUMP, NEEDS NEW PAD STANDS, NEW UMP PADS, NEEDS NEW 3/8 FLOAT AND NEW A48 BELT. BOTTOM OF WET SECTION IS RUSTED OUT WATER IS LEAKING OUT. NEED TO REPLACE

Near W Washington St, Phoenix, AZ 85009
Phoenix, AZ - In Phoenix, AZ:  COOLER #1 NEEDS WET SECTION PRESSURE WASH CLEAN OUT. NEEDS NEW A48 BELT, NEEDS NEW 3/8 FLOAT, NEEDS NEW PADS FOR SERIAL #25076. AND NEEDS NEW UMP PUMP AS WELL. WET SECTION IS RUSTED BADLY.

COOLER #2 WET SECTION NEEDS PRESSURE WASH CLEAN OUT. NEEDS NEW 3/8 FLOAT. NEEDS NEW A48 BELT AND NEEDS NEW PADS FOR SERIAL #25071. PUMP IS WORKING, WET SECTION IS VERY RUSTED OUT.

COOLER #3. NEEDS NEW UMP PADS FOR SERIAL #25070. NEEDS NEW A48 BELT AND NEW A48 BELT AND WET SECTION PRESSURE WASH CLEAN OUT. WET SECTION IS VERY RUSTED.

COOLER #4 NEEDS NEW A48 BELT. NEW UMP PADS FOR SERIAL#25072. AND LIGHT WET SECTION CLEAN OUT.

COOLER #5 NEEDS NEW 3/8 FLOAT. NEED NEW 3/8 COPPER LINE. NEED TO PRESSURE WASH WET SECTION AND NEW 1/2 WATER SHUT OFF VALVE AND NEW UMP PUMP.  PADS ARE IN GOOD CONDITION.

COOLER #6 NEEDS A NEW UMP PUMP, NEEDS NEW PAD STANDS, NEW UMP PADS, NEEDS NEW 3/8 FLOAT AND NEW A48 BELT. BOTTOM OF WET SECTION IS RUSTED OUT WATER IS LEAKING OUT. NEED TO REPLACE
Brian S.

Brian S.

In Phoenix, AZ: CHECKED CLOSET AIR HANDLER SYSTEM BLOWER MOTOR AMPS RATED AT 6.0 ACTUAL READING IS 5.57. BLOWER MOTOR IS COATED WITH OIL AND DIRT MOTOR IS HIGH AMPING. AIR HANDLER IS 36 YEARS OLD. COPPER LINE SET WAS REPLACED AT ONE TIME AND OLD ONE WAS LEFT IN THE CLOSET. THERMOSTAT IS WORKING PROPERLY. TOOK SPLIT TEMPERATURES RETURN IS 78.0 SUPPLY IS 59.2. CHECKED CONDENSER FREON LEVELS ARE GOOD SYSTEM IS R22 FREON THAT HAS GONE OUT OF SERVICE. CONDENSER IS 7 YEARS OLD COMPRESSOR IS RATED AT 25.0 ACTUAL IS 15.88. OUTDOOR FAN MOTOR IS RATED AT 1.1 ACTUAL IS .96. BOTH ARE IN SPECIFICATION CHECKED RUN CAPACITOR RATED AT 80/5/440 ACTUAL 83.2/5.2/440 IN SPECIFICATION.SYSTEM IS MIX MATCHED GOODMAN CONDENSER WITH TRANE AIR HANDLER BUT IS RUNNING OK. CHECKED DUCT WORK MOST OF THE DUCT WORK IS SOFFITT HARD DUCT WORK HAVE TWO RUNS OF FLEX ONE NEWER ONE OLDER BOTH ARE SEALED. ATTIC INSULATION LOOKS OK HAVE 9” AND SOME AREAS ARE 12”. A/C SYSTEM IS RUNNING OK BUT WOULD RECOMMEND REPLACING SYSTEM

Near S 41st St, Phoenix, AZ 85044
Phoenix, AZ - In Phoenix, AZ:  CHECKED CLOSET AIR HANDLER SYSTEM BLOWER MOTOR AMPS RATED AT 6.0 ACTUAL READING IS 5.57. BLOWER MOTOR IS COATED WITH OIL AND DIRT MOTOR IS HIGH AMPING. AIR HANDLER IS 36 YEARS OLD. COPPER LINE SET WAS REPLACED AT ONE TIME AND OLD ONE WAS LEFT IN THE CLOSET. THERMOSTAT IS WORKING PROPERLY. TOOK SPLIT TEMPERATURES RETURN IS 78.0 SUPPLY IS 59.2. CHECKED CONDENSER FREON LEVELS ARE GOOD SYSTEM IS R22 FREON THAT HAS GONE OUT OF SERVICE. CONDENSER IS 7 YEARS OLD COMPRESSOR IS RATED AT 25.0 ACTUAL IS 15.88. OUTDOOR FAN MOTOR IS RATED AT 1.1 ACTUAL IS .96. BOTH ARE IN SPECIFICATION CHECKED RUN CAPACITOR RATED AT 80/5/440 ACTUAL 83.2/5.2/440 IN SPECIFICATION.SYSTEM IS MIX MATCHED GOODMAN CONDENSER WITH TRANE AIR HANDLER BUT IS RUNNING OK. CHECKED DUCT WORK MOST OF THE DUCT WORK IS SOFFITT HARD DUCT WORK HAVE TWO RUNS OF FLEX ONE NEWER ONE OLDER BOTH ARE SEALED. ATTIC INSULATION LOOKS OK HAVE 9” AND SOME AREAS ARE 12”. A/C SYSTEM IS RUNNING OK BUT WOULD RECOMMEND REPLACING SYSTEM
Tom G.

Tom G.

In Phoenix, AZ: Inspect two systems during gas inspection. Package unit over school area. And main split system for home. Inspected supply lines that run on exterior of home. Inspected water heater connections. No gas leaks at this time. Service completed.

Near E Fairmount Ave, Phoenix, AZ 85018
Phoenix, AZ - In Phoenix, AZ:  Inspect two systems during gas inspection. Package unit over school area. And main split system for home. Inspected supply lines that run on exterior of home. Inspected water heater connections. No gas leaks at this time. Service completed.
Leonardo G.

Leonardo G.

In Phoenix, AZ: UPON ARRIVAL REMOVED EXISTING PADS AND CLEANED PANELS AS WELL. INSTALLED NEW PADS AND CUT THEM TO SIZE FIT THE PANEL. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN SPEC.

Near N 28th St, Phoenix, AZ 85050
Leonardo G.

Leonardo G.

In Phoenix, AZ: UPON ARRIVAL CYCLED UNIT INTO COOLING MODE COOLING MODE. LEFT HOMEOWNER WITH INTAKE FILTER. TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. WASHED AND RINSED OUTDOOR COILS.

Near E Villa Theresa Dr, Phoenix, AZ 85032
Leonardo G.

Leonardo G.

In Phoenix, AZ: UPON ARRIVAL CYCLED UNIT INTO COOLING MODE REPLACED INTAKE FILTERS AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.

Near N 29th St, Phoenix, AZ 85016
Phoenix, AZ - In Phoenix, AZ:  UPON ARRIVAL CYCLED UNIT INTO COOLING MODE REPLACED INTAKE FILTERS AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.
Leonardo G.

Leonardo G.

In Phoenix, AZ: CLEANED OUT WET SECTION ON COOLER. OILED MOTOR AND PILLOW BEARINGS. TURNED WATER BACK ON SET FLOAT LEVEL. REMOVED WATER LINE AND CLEANED OUT. CHECKED MOTOR AMPS ALL LOOK GOOD CLEANED PUMP BASKETS AND. CHECKED PUMPS BOTH WORKING PROPER. BELT IS OLDER BUT NO CRACKING YET READJUSTED BELT ALL WORKING PROPER.

Near N 16th Ave, Phoenix, AZ 85015
Leonardo G.

Leonardo G.

In Phoenix, AZ: UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. WASHED AND DRIED AIR CARE FILTER. TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.

Near W Redfield Rd, Phoenix, AZ 85053
Leonardo G.

Leonardo G.

In Phoenix, AZ: UPON ARRIVAL CYCLED UNITS INTO COOLING MODE. TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT CONDENSERS CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.

Near N 22nd Pl, Phoenix, AZ 85028
Tom G.

Tom G.

In Phoenix, AZ: UPON ARRIVAL FOUND PRIMARY PAN OVER FLOWING. CLEARED PRIMARY LINE AND CLEANED OUT P TRAP AT SINK. REPIPED LINE TO HELP WATER FLOW. TESTED LINE AFTER REPAIR SYSTEM WORKING PROPERLY.

Near N 20th St, Phoenix, AZ 85016
Phoenix, AZ - In Phoenix, AZ:  UPON ARRIVAL FOUND PRIMARY PAN OVER FLOWING. CLEARED PRIMARY LINE AND CLEANED OUT P TRAP AT SINK. REPIPED LINE TO HELP WATER FLOW. TESTED LINE AFTER REPAIR SYSTEM WORKING PROPERLY.
Leonardo G.

Leonardo G.

In PHoenix, AZ: UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. REPLACED INTAKE FILTERS AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL. WASHED AND RINSED OUTDOOR COILS. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.

Near W Roeser Rd, Phoenix, AZ 85041
Leonardo G.

Leonardo G.

In Phoenix, AZ: UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. REPLACED INTAKE FILTERS AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.

Near E Marco Polo Rd, Phoenix, AZ 85024
Phoenix, AZ - In Phoenix, AZ:  	UPON ARRIVAL CYCLED UNIT INTO COOLING MODE. REPLACED INTAKE FILTERS AND TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. AT UNIT CLEANED AND TIGHTENED ELECTRICAL CONNECTIONS. TOOK VOLTS AND AMP DRAWS FROM COMPONENTS. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN MANUFACTURER SPECIFICATIONS.
Brian S.

Brian S.

In Phoenix, AZ: FOUND 8 MIDEA PADS SAGGING VERY BAD NEEDS NEW COOLER PADS. RECIRCULATING PUMP IS LOCKED UP NEEDS NEW 240 VOLT PUMP. CUSTOMER WANTS TO DO PADS WANTS TO WAIT ON DRAIN PUMP.

Near W Purdue Ave, Phoenix, AZ 85051
Leonardo G.

Leonardo G.

In Phoenix, AZ: UPON ARRIVAL FILLED WET SECTION WITH WATER. PUT BELT BACK ON MOTOR AND PUT OVERFLOW KIT . LUBRICATED BEARINGS AND ADJUSTED FLOAT. UPON DEPARTURE UNIT WORKING PROPERLY AND WITHIN SPEC. PLEASE REFER TO CHECKLIST FOR FURTHER DETAILS AND INFORMATION .

Near W Willetta St, Phoenix, AZ 85007
Leonardo G.

Leonardo G.

In Phoenix, AZ: UPON ARRIVAL CYCLED ALL THREE UNITS INTO COOLING MODE . NOTICED SOME THERMOSTATS SET LOWER THAN OTHER ONES. TOOK TEMPERATURE READINGS FROM SUPPLY AND RETURN. 20 + DEGREE DIFFERENTIAL FROM RETURN AND SUPPLY. AT UNITS MADE SURE BELTS WERE TIGHT AND CHECKED FREON LEVELS WITH SUPER HEAT AND SUBCOOL (WITHIN SPEC). DID NOTICE FILTRATION WAS RESTRICTED AND NEED REPLACEMENT OF FILTERS. FOUND NO ISSUE WITH SYSTEMS. NEED THERMOSTATS TO BE SET AROUND SAME TEMPERATURE FOR UNITS NOT TO OVER WORK.

Near N 44th St, Phoenix, AZ 85008
Tom G.

Tom G.

In Phoenix, AZ: Preventative Maintenance on rooftop unit.

Near E Vista Bonita Dr, Phoenix, AZ 85024
Phoenix, AZ - In Phoenix, AZ:  Preventative Maintenance on rooftop unit.
Tom G.

Tom G.

In Phoenix, AZ: Upon arrival cycled systems. Upstairs system is low on Freon due to an ongoing leak in evaporative coil. Recommend replacement of system. Customer is selling house wants the most cost effective repair. No warranty on Freon. Serviced systems in accordance with maintenance checklist. Services completed.

Near E Mossman Dr, Phoenix, AZ 85050
Phoenix, AZ - In Phoenix, AZ:  Upon arrival cycled systems. Upstairs system is low on Freon due to an ongoing leak in evaporative coil. Recommend replacement of system. Customer is selling house wants the most cost effective repair. No warranty on Freon. Serviced systems in accordance with maintenance checklist. Services completed.
Brian S.

Brian S.

In Phoenix, AZ: At a local commercial building. COOLER #2 CLEANED OUT WET SECTION. TURNED ON WATER. CHECKED FLOAT AND FLOAT WILL NOT SHUT OFF, NEEDS NEW 3/8 FLOAT. TURNED ON PUMP PUMP IS WORKING BUT PADS ARE IN HORRIBLE SHAPE RECOMMEND NEW PADS. ONE LEG DOES NOT HAVE POWER MOTOR WILL NOT START CHECKED POWER ISSUE ONE LEG ON THE SYSTEM IS DEAD RECOMMEND GETTING AN ELECTRICIAN TO LOOK AT WIRING ISSUE COULD NOT PULL APART BREAKER BOX BECAUSE IT IS LOCKED. 30 AMP FUSES ARE ALSO BLOWN. COOLER #1 CLEANED OUT WET SECTION. FILLED WITH WATER, FLOAT IS IN BAD SHAPE RECOMMEND NEW 3/8 FLOAT. PADS ARE IN BAD SHAPE AND NEED REPLACED. COOLER WHEEL IS OLD AND MAKING NOISE BUT IS WORKING.

Near N 26th Ave, Phoenix, AZ 85027